Local Administration Identified conditions of fuel stations
Category: Fuel | Posted on: 5-01-2009
Syrian Minister of Local Administration and Environment Hilal al-Atrash was issued resolution No. 211 set the conditions to be provided in the fuel stations, which are classified as Class III industries, allowing the fuel stations to be set up outside the campus of the direct road and out of a protection in accordance with the provisions of the Act 26 of 2006.
The ministry identified the conditions required in connection with the urban area would be allowed in designated areas under the regulatory facsimile certified in commercial and industrial areas, provided at least not the way to be introduced with the establishment of the station platforms of at least 24 m after the reservoirs on the outer limits of the station from all sides for 5 m.
It also be allowed in residential areas platforms with 20 m in the rural areas that some reservoirs, pumps about 5 meters from the outer limits of the station in the tourist areas to reservoirs, pumps about a distance of at least 15 meters from the border out borders of the terminal and allow the establishment of non-fuel cars stations in the areas allocated to the stores also identified the conditions of the plant site, where a serviced routes of entry and exit lanes and to ensure the slow acceleration of the technical specifications determined by the separation of entry and exit to the station on the main road Islands does not allow a solid cross to the indiscriminate and non-establishment stations on the public square and that the distance between the station and the other of not less than 3 km with exceptions to the urban centers stations.
It also identified the area within the city planning on the estate area of not less than 500 m 2 in the absence of service centers from the car wash and lubrication and 700 m 2 in the event of existence of the 1000 2 out of planning boundaries in 1500 and 2 stations in the tourist areas but at least the length of the front of the station on the property 25- 2m.
The instructions indicated that the conditions to be provided by the buildings must be of the non-combustible floor is one with insurance, the water should not exceed an area of 30% of the construction area of the property and set conditions for the storage tanks and the distances between the capacity and services, lighting, electrical, etc. provide fire protection equipment and pumps security and safety conditions and paintings extension.